WNS horizontal internal combustion gas-fired boiler

WNS horizontal internal combustion gas-fired boiler

Fuel type: natural gas
Typical application: garment factories, laundries, food manufacturers, power plants, district heating, schools, hospitals, heating and industrial steam and hot water supply etc.
Thermal efficiency: ≥100%
Boiler capacity: 1 – 10t/h

The WNS horizontal internal combustion three-pass full wet-back boiler is fitted with a fully corrugated furnace, which increases the heat transfer area and bolsters stability. It is constructed using the full flange butt welding technique reducing thermal stress of the furnace. The tubes are welded to the tube plates using the ‘expand first, then weld’ technique, which eliminates corrosion problems and prolongs the lifespan of the boiler. The smoke tubes come with helical internal ribs which improve the heat exchange coefficient of the boiler. The WNS series are highly thermal efficient with low fuel consumptions. They have a high degree of automation, stable outputs, and are easy to maintain. The installation is relatively simple and less time consuming.

FEATURES

Complete combustion system

100% corrugated furnace with large combustion chamber

Advanced engineering

Thermal efficiency ≥92%
Dual fuel design
Automatic control system

Low carbon footprint and eco-friendly

Compliant with national manufacturing specifications

Investment cost

Abundant fuel sources with stable prices
Automatic feeding system minimising human intervention
Only requires one operator

SPECIFICATION

Model
WNS0.5-0.7-Y、Q-| WNS1-1.0-Y/Q WNS2-1.25-Y/Q WNS3-1.25-Y/Q WNS4-1.25-Y/Q WNS6-1.25-Y/Q WNS8-1.25-Y/Q WNS10-1.25-Y/Q WNS12-1.25-Y/Q WNS15-1.25-Y/Q WNS20-1.25-Y/Q
Speficiation Rated evaporation t/h 0.5 1 2 3 4 6 8 10 12 15 20
Rated steam pressure Mpa 0.7 1.0 1.25/1.6
Rated steam temperature 170 184 193.3/204
Design exhaust temperature 150
Boiler full water volume L 1350 2832 4520 6900 7300 7677 12700 17400 29500 37049 42500
Design thermal efficiency % ≥92
Heated surface Ontology m2 15.5 24.5 50.6 82.9 100.7 162.31 209.26 252.4 354 364.1 493
Economizer(Atmospheric) m2 / 12.9 21 27 41.5 /
Steel economizer(Pressure) m2 / 32 43 54 65 81 108
Fuel consumption Natural gas Nm³/h 40.94 78.87 158.37 237.51 316.68 411.16 559.6 699.5 803.4 1004.25 1339
Pipe Main steam valve diameter DN 40 50 80 100 125 150 200 225
Water inlet diameter DN 25 32 40 50 80 65
Safety valve diameter mm 40 50 65 50*2 65*2 80*2 100*2
Blowoff valve diameter DN 40 50 50*2 65*2
Chimney Φ 280 300 350 400 450 500 600 700 800 900 1000
Overall size Weight t 2.8 4.6 7.6 11.2 12.5 17.6 21 25 37 39 48
Length mm 3464 3840 4620 5126 5840 6334 6894 7816 8355 8379 9230
Width mm 1600 1760 1980 2300 2432 3062 2766 3250 3636 3650
Height mm 1790 2064 2367 2718 2872 3368 3468 3840 3707 4250
Pump Model QDL2-11 QDL2-16 QDL4-18 QDL4-20 QDL8-19 QDL8-20 QDL12.5-11 QDL12.5-13 QDL18-12 QDL18-13 DLG-G36*6
Input power Kw 1.4 3 4 7.5 11 15 18.5 22 30
X